How To Select The Right Gas Analyser For Your Business
Gas analysers are incredibly important pieces of equipment in a variety of industries. By measuring the gases in the air, they are able to detect problems and alert people as quickly as possible to ensure that workers and anyone in the surrounding area is kept safe.
There are different types of gas analysers available, so to explain further, CEM Solutions, specialists in continuous emissions monitoring, explore the options to help you decide which one is right for your business.
Contents |
[edit] First, you need to identify what type of gas needs to be measured
The first thing to think about is the type of gas that you are required to measure, as different analysers will be set up to detect specific gases. They may include:
- Carbon Dioxide (CO)
- Methane (CH)
- Carbon Monoxide (CO)
- Volatile Organic Compounds (VOCs)
- Hydrogen Sulphide (HS)
- Nitrogen Oxide (NO or NO)
- Oxygen (O)
- Ammonia (NH)
Once you’ve identified the type of gas, you can then consider which type of gas analyser will be most suitable for your environment and monitoring requirements, for example:
Infrared analysers detect gases such as carbon dioxide and methane by measuring the absorption of infrared light.
Photoionisation detectors (PID) are extremely effective for detecting volatile organic compounds (VOCs) and some toxic gases at low concentrations, whilst paramagnetic analysers are better suited for measuring oxygen concentrations in both process and ambient environments.
There are also thermal conductivity detectors (TCDs) that can measure binary gas mixtures and are often used in applications that require hydrogen, helium, or argon analysis.
However, electrochemical sensors are better at detecting toxic gases like carbon monoxide or hydrogen sulphide by using a chemical reaction that can produce a measurable electrical signal to determine gas concentration.
Tunable Diode Laser Absorption Spectroscopy (TDLAS) analysers are useful for selective measurements of gases like ammonia and methane, particularly where high precision and fast response times are needed.
You may also want to consider the function of the equipment, i.e., whether it’s a handheld gas analyser, or a fixed gas analyser. This is usually determined by the type of gas you need to monitor, and how hazardous the environment may be.
[edit] The required levels of sensitivity
In addition to the type of gas you are looking to monitor, you also need to think about the measurement range and sensitivity of your analyser. Some applications might require the detection of low concentrations of gas, while others will require measurement over a wide range of concentrations.
High sensitivity analysers like TDLAS analysers are essential if you are looking for trace amounts of gas in things like leak detection, greenhouse gas monitoring or safety applications.
Depending on your application, other options such as electrochemical sensors for low-level toxic gases or photoacoustic spectroscopy analysers for trace gas monitoring may also offer suitable sensitivity and accuracy.
Gas chromatography (GC) systems with thermal conductivity or flame ionisation detectors also allow sensitive multi-gas measurements.
You should also think about the lower detection limit and upper detection limit of the analyser, as these specifications will determine the range in which the analyser can provide reliable measurements.
[edit] The chosen environment
The environment in which the analyser is to be used is also an important factor. Harsh environments with high temperatures, humidity and dust will need an analyser with a rugged design and non-contact measurement capabilities.
Many industrial environments use a combination of analyser types, including electrochemical, paramagnetic and infrared analysers, which can be housed in rugged explosion-proof enclosures.
Gas chromatographs are preferred in applications requiring the separation and analysis of complex gas mixtures, such as in refining or petrochemical processes, whilst portable multi-gas detectors, often equipped with multiple sensor technologies, are ideal for remote or field operations.
[edit] Response times
If you are in an environment where conditions can change rapidly, you need to think carefully about the response time of your chosen gas analyser. In a combustion control environment, speed is of the essence in order to maintain optimal combustion efficiency and minimise any emissions.
Confined spaces will also require fast response times to detect any dangerous gas levels and initiate corrective actions. The response time is usually measured in terms of the time required for the analyser to reach a certain percentage of the final value after a change in gas concentration. Shorter response times are usually preferred for dynamic processes.
While TDLAS is known for fast response, other technologies such as electrochemical sensors and NDIR also provide quick and reliable readings depending on the setup. For complex multi-component analysis, gas chromatography may have longer response times but can also provide more detailed insight into gas composition.
When selecting a gas analyser, you need to carefully consider all of the factors, including the type of gas that needs to be measured and the sensitivity, response time, and application environment. This will help you narrow down the most appropriate gas analyser for your business and ensure a safe environment for everyone.
Featured articles and news
We're expanding our collaborative mission by launching DB Intelligence, an exclusive market research advisory panel. Built environment professionals can now get paid to share their expertise on industry trends, products and services.
Panel members receive direct financial incentives for participating in research projects like short surveys, 1-2-1 interviews and focus groups. Register today to shape the future of the construction sector.
Planning condition discharge in England and Wales
A brief exoplanation from a building compliance expert, with further links.
Overheating guidance and tools for building designers
Guidance for dealing with element of building fabric control that have increasing importance.
Shading for housing, a design guide
From the Good Homes Alliance and British Blind and Shutter Association.
UK Standard Skills Classification (SSC)
A shared framework for describing skills needs.
Social media ban consultation comes to close
CIOB urges UK Government to consider social media’s role in careers guidance in ban debate.
The latest of eight Skills England apprenticeship units
The addition of battery manufacturing welcomed by ECA with a warning about the risks of fast-tracked apprenticeship units.
Building Control Independent Panel final report
A precis of a key report led by Dame Hackitt with full recommendations and link to the government response.
Building Safety recap April, 2026
A short and longer run-through of the month, with links to further information and sources.
CIAT May 2026 briefing.
From medieval scribes to modern word art.
ECA welcomes crackdown on late payment and push for clean energy, whilst CIOB seek fixed cladding removal timeframes.
Cyber Security in the Built Environment
Protecting projects, data, and digital assets: A CIOB Academy TIS.
Managing competence in the built environment
ITFG publishes new industry guide on how to meet the ICC principles.
The UK's campaign to reduce noise pollution: Mythbusting, articles and topic guides.